Exhibition Invitation | Palas® invites you to attend 2024 Filter Industry Annual Conference

Palas® will participate in the “2024 Filter Industry Annual Conference” and “Filter Innovation and Development and Frontier Technology Exchange Conference” from 13th to 14th November, 2024 in Qinghe, Hebei, China. On that occasion, Palas® will focus on promoting the FET series of filter element filtration performance test system, DFP series of compressed air filter test rig, HMT series of crankcase ventilated oil mist separator test rig, Promo series of aerosol particle size spectrometer, and various types of aerosol generators. At the invitation of the organizer, China Internal Combustion Engine Industry Association Filter Branch, Palas® will set up a booth at the Qinghe Qingcheng Hotel. You are welcome to visit us, and we sincerely look forward to your presence!

First Look Hot Products

Palas® FET Air Filter Performance Test System


FET DUAL

Advantages
·   Accurate test, wide range of application
→ Supports classifying efficiency test in the range of 20nm – 400nm according to ISO29463-5/IEST 7.3.
→ Supports dust loading and classifying efficiency testing in the range of 0.3 – 10μm according to ISO 11155-1/ISO 16890-3 and other standards.
·   Flexible and easy to use
→ Provide different sizes of test ducts, support the maximum size of 610mmx610mm or 305mmx305mm filter element testing.
→ Supports customized cartridge adapters to meet different cartridge sizes in the same duct for excellent test performance.
→ For large particle size measurement, equipped with dual measurement devices to ensure the accuracy and reliability of the test results.
·   Accuracy
With professional operation and analysis software to ensure the reliability of testing and data analysis.
→ Provide professional test reports to assist product development and project development, reducing the company’s R&D investment.
→ Imported from Germany

Palas® DFP 3000 Series Compressed Air Filter Test Rig

The Palas® DFP 3000 Compressed Air Filter Test Rig is designed to test the classification efficiency of compressed air filters, natural gas filters or compressor oil-air separators at 7 bar, according to ISO 12500-1/-3, and is available in a special version to simulate the classification efficiency at up to 7 bar and 80°C. The test rig can also be equipped with an optional adapter to test material classification efficiencies at up to 4 bar. An optional filter material adapter is also available to test the classification efficiency of materials at pressures up to 4 bar.

Advantages
·   Testing is done at up to 7 bar and 80°C to simulate real world conditions.
·   2μm – 40μm particle size measurement range (segmented)
·   Isothermal and isobaric particle sampling and measurement system to minimize deviations in the particle size distribution caused by pressure relief and cooling.
·   Capability for oily and dusty particles
·   Adjustable refractive index for more accurate information on the mass concentration of oily particles.
·   Flexible and powerful test rig control and analysis software, FT Control.
·   Flexible and programmable sequence programs for pressure loss measurements, classification efficiency measurements and during loading measurements.
·   Fully automated and repeatable test scripts, including pressure and volume flow control, for one-button completion of test tasks.
·   Measurement equipment supports user-completed calibration to ensure the accuracy of test results.

Applications
·   Compressed air and natural gas filters
·   Oil and gas separators for air compressors
·   Filter Media Testing

Palas® HMT Series Crankcase Ventilation Oil Mist Separator Test Rig
Oil Mist Separator Filtration Performance Test Rig according to ISO 17536

The maximum temperature of gas channeling in the engine can reach 120°C, and the oil mist separator used for purifying gas channeling mostly works under negative pressure conditions. To help users test the efficiency of oil mist separators under simulated operating conditions, Palas® provides users with the HMT 1000 P oil mist separator filtration performance test rig. The HMT 1000 P can test the classification efficiency of the oil mist separator, the total separation efficiency, the weighing method efficiency (optional), and the pressure drop of the product at absolute pressures up to 120°C and below 900mbar. Thanks to the modular design, the core components of the test stand (such as the Promo 1000 HP, the PROMO 1000 HP, the LDD 100 H, the isothermal sampling tube, etc.) can be easily removed from the HMT 1000 P. The filtration performance test system of HMT Portable engine platform oil mist separator was constructed to measure the filtration performance of the oil mist separator in situ on the engine platform.

Advantages
·   Measurement and evaluation of counting and weighing filtration efficiencies
·   Isothermal measurement of the entire pipeline to avoid changes in particle size distribution due to temperature drop
·   Supports testing at temperatures up to 120°C.
·   High reproducibility of the test method
·   Cross-country comparison of measurement results due to the wide use of the measuring system
·   Cleaning and calibration can be carried out independently by the customer.
·   Easy to operate, even untrained personnel can quickly use the equipment
·   Supports the completion of engine rig tests using the core product
·   Functionality of individual components and entire systems can be verified before and during delivery
·   Reliable operation
·   Short setup times and very low maintenance costs
·   Reduce your operating costs

Applications
·   Quality control of oil mist separators
·   Further development of oil mist separators, e.g. polymerizers, cyclones and other inertial separators, electric filters and filter combinations for:
     → Gas leakage
     → Oil mist downstream of compressors
     → Cooling lubricants on machines
     → Minimal lubrication aerosols

Palas® Promo® Series Aerosol Spectrometer

The unique design of the Palas® Promo® Particle size spectrometer series enables it to reach the maximum concentration of 106 particles/cm3 particles without the need for a dilution system. 256 original sampling channels can output up to 128 channels of particle size distribution information. Replaceable sensors make the device more flexible and suitable for different scenarios. High temperature and high-pressure sensors are available, allowing up to 10 bar pressures and temperatures from -120 ° C to 470 ° C. The range includes Palas® Promo® 2000, Palas® Promo® 3000, Palas® Promo® 3000HP and other products to provide a personalized solution to your needs.

Advantages
·   Measuring range of 0.2 to 100 μm (4 measuring ranges selectable in one device)
·   Up to four measuring ranges in only one device:
     → 0,2 μm – 10 μm
     → 0,3 μm – 17 μm
     → 0,6 μm – 40 μm
     → 2 μm– 100 μm (additionally for sensors 2300 and 2500)
·   Up to 128 size channels per measuring range
·   Concentration range of 1 particle/cm3 to 106 particles/cm3
·   Calibration curves for different refractive indices
·   Very high and reproducible counting efficiency rate starting at 0.2 μm
·   Pressure resistance up to 10 bar (optional)
·   Can be heated up to 250°C (optional)
·   Optical fibre technology
·   Simple operation with a large touch display
·   Calibration, cleaning and lamp replacement can all be performed independently by the customer
·   External control by RS 232 or Ethernet
·   With analysis software PDAnalyze

Applications
·   Emission monitoring of installations
·   Control of grinding and classification processes
·   Monitoring of production processes in the food, pharmaceuticals and chemicals industries
·   Testing of complete filters, inertial and wet separators or electrostatic precipitators

Palas® RBG Aerosol Generator



 

The generation of low concentration solid particulate aerosols from dusts and powders is suitable for many applications such as research, development and quality control of calibration test rigs for particulate measurement equipment. The stability of the generator in terms of single shot dust production and lower feed rates are necessary for the generation of low concentration solid particulate aerosols. In addition, the reproducibility of the aerosol generation process must be ensured, and the RBG system meets these requirements in the mass flow range of 0.04 g/h – 800 g/h. For mass flow rates from 40 mg/h to 800 g/h, the three new aerosol generators RBG Professional, RBG basic and RBG solo fulfill the requirements from research to quality assurance and calibration. The feeding of storage vessels filled with dust or powder is provided by advanced stepper motor technology to ensure precise feeding to the dispersing brush over a wide mass range.

Advantages
·   Overpressure operation up to 10 bar
·   Wider Mass Flow Range
·   8mg/m 3 stable mass concentration capacity
·   100 hours of continuous work
·   Remote control

Applications
·   Test of cabin filter
·   Development of new filter and filter material
·   Calibration
·   Particle image velocimetry
·   Inhalation test
·   Mask check

For more product information, you are welcome to visit us at the Palas® booth at the Qinghe Qingcheng Hotel in Hebei, China from 13th to 14th November 2024 and we look forward to seeing you there.

Palas® organizes a series of events on various topics to share professional knowledge of aerosol measurement technology. Palas® technical experts and industry scholars from all over the world will give you detailed online explanations. Welcome to register to attend and learn more about the conference as soon as possible!

Date Time Topic
2024/11/27-28 14:00-17:50,

09:30-17:30

Palas® Autumn Training Event 2024 – Wuhan Offline-Roadshow
2024/12/11 16:00-17:00 Hyperlocal Sensor Grids in AQM Networks – How to Make Your Data Interpretable? Webinar
2025/2/26-27 9:30-17:00

9:00-17:30

Air Quality Forum 2025 – Brussels, Belgium Offline-Forum

Click to Register