{"id":8765,"date":"2023-05-15T11:32:38","date_gmt":"2023-05-15T03:32:38","guid":{"rendered":"https:\/\/palas.com.cn\/en\/?p=8765"},"modified":"2023-05-22T11:37:23","modified_gmt":"2023-05-22T03:37:23","slug":"news-2023-05-12","status":"publish","type":"post","link":"https:\/\/palas.com.cn\/en\/news-2023-05-12\/","title":{"rendered":"How Palas\u00ae Aerosol Spectrometer Can Help Biofuel at High Temperatures and Pressures"},"content":{"rendered":"<p>Gas cleaning has always been an issue in the field of biofuel projects. It is often necessary to purify feedstock gases from combustion waste and test its purification effect, often at high temperatures and pressures. This is a significant challenge for gas measurement and separation.<\/p>\n<p>Palas\u00ae Promo\u00ae 3000HP Aerosol Spectrometer enables particle size characterization at high temperatures and pressures, providing data on the distribution of aerosols. With the necessary particle measurement technology, researchers in Karlsruhe chose Palas\u00ae Promo\u00ae 3000HP Aerosol Spectrometer for reliable data on the project \u201cbiofuel\u201d.<\/p>\n<p><img loading=\"lazy\" class=\"wp-image-8767\" src=\"https:\/\/palas.com.cn\/en\/wp-content\/uploads\/2023\/05\/1-2.jpg\" alt=\"\" width=\"500\" height=\"538\" srcset=\"https:\/\/palas.com.cn\/en\/wp-content\/uploads\/2023\/05\/1-2.jpg 800w, https:\/\/palas.com.cn\/en\/wp-content\/uploads\/2023\/05\/1-2-279x300.jpg 279w, https:\/\/palas.com.cn\/en\/wp-content\/uploads\/2023\/05\/1-2-768x826.jpg 768w, https:\/\/palas.com.cn\/en\/wp-content\/uploads\/2023\/05\/1-2-22x24.jpg 22w, https:\/\/palas.com.cn\/en\/wp-content\/uploads\/2023\/05\/1-2-33x36.jpg 33w, https:\/\/palas.com.cn\/en\/wp-content\/uploads\/2023\/05\/1-2-45x48.jpg 45w, https:\/\/palas.com.cn\/en\/wp-content\/uploads\/2023\/05\/1-2-600x645.jpg 600w\" sizes=\"(max-width: 500px) 100vw, 500px\" \/><br \/>\n<em>Forschungszentrum Karlsruhe (KIT building) <\/em><\/p>\n<p><strong>Challenges for biofuel<\/strong><\/p>\n<p>&#8220;After the gasification, we have to work up the raw gas for the fuel synthesis,&#8221; declares Dipl.-Ing. Robert Mai from the institute. The project is engaged in biofuel research, extracting fuel from straw and wood waste. Analyzing and participating impurities (soot particles, sulfur, hydrogen chloride, etc.) in raw fuel gas is vital to fuel composition. And because of the flammable nature of the catalyst, protecting it from an explosion is also important.<\/p>\n<p><img loading=\"lazy\" class=\"wp-image-8768 size-full\" src=\"https:\/\/palas.com.cn\/en\/wp-content\/uploads\/2023\/05\/2-2.jpg\" alt=\"\" width=\"360\" height=\"221\" srcset=\"https:\/\/palas.com.cn\/en\/wp-content\/uploads\/2023\/05\/2-2.jpg 360w, https:\/\/palas.com.cn\/en\/wp-content\/uploads\/2023\/05\/2-2-300x184.jpg 300w, https:\/\/palas.com.cn\/en\/wp-content\/uploads\/2023\/05\/2-2-24x15.jpg 24w, https:\/\/palas.com.cn\/en\/wp-content\/uploads\/2023\/05\/2-2-36x22.jpg 36w, https:\/\/palas.com.cn\/en\/wp-content\/uploads\/2023\/05\/2-2-48x29.jpg 48w\" sizes=\"(max-width: 360px) 100vw, 360px\" \/><br \/>\n<em>Dipl.-Ing. Robert Mai at the pilot plant system of the biofuel project<\/em><\/p>\n<p>Promo\u00ae 3000HP can provide particle concentration and distribution measurements for the filtration and cleaning conditions at 250 \u00b0C and 10 bar. The actual procedure shall be conducted at approximately 600\u00b0C and 80 bar. And the pilot plant system must be reached at least 200 \u00b0C to avoid condensation. However, gas measurements cannot be made under these conditions, so a secondary flow shall be separated and cooled to 200 \u00b0C. Then it can lead to the aerosol sensor without pressure.<\/p>\n<p>The separate external sensor communicates with the data control unit via fiber optics. It\u2019s suitable for monitoring flammable and explosive aerosols, avoiding contact between the cable and the flammable gas. Promo\u00ae 3000HP serves to protect the flammable catalyst and ensures a safe environment. Moreover, comparing the data before and after purification is required to check the cleaning effect. In Promo\u00ae 3000HP, an automatic and optical switch between raw and clean gas sensors is integrated, which enables rapid filter testing. While the two sensors for measuring the raw and the purged gas can be connected via optical fiber: while welas\u00ae sensor 2070 H is used for detecting raw gases at high concentrations, welas\u00ae sensor 2300 H is used for detecting purged gases at concentrations below 10 mg\/m<sup>3<\/sup>.<\/p>\n<p><img loading=\"lazy\" class=\"wp-image-8770\" src=\"https:\/\/palas.com.cn\/en\/wp-content\/uploads\/2023\/05\/3-1.jpg\" alt=\"\" width=\"500\" height=\"269\" srcset=\"https:\/\/palas.com.cn\/en\/wp-content\/uploads\/2023\/05\/3-1.jpg 1279w, https:\/\/palas.com.cn\/en\/wp-content\/uploads\/2023\/05\/3-1-300x161.jpg 300w, https:\/\/palas.com.cn\/en\/wp-content\/uploads\/2023\/05\/3-1-1024x551.jpg 1024w, https:\/\/palas.com.cn\/en\/wp-content\/uploads\/2023\/05\/3-1-768x413.jpg 768w, https:\/\/palas.com.cn\/en\/wp-content\/uploads\/2023\/05\/3-1-24x13.jpg 24w, https:\/\/palas.com.cn\/en\/wp-content\/uploads\/2023\/05\/3-1-36x19.jpg 36w, https:\/\/palas.com.cn\/en\/wp-content\/uploads\/2023\/05\/3-1-48x26.jpg 48w, https:\/\/palas.com.cn\/en\/wp-content\/uploads\/2023\/05\/3-1-600x323.jpg 600w\" sizes=\"(max-width: 500px) 100vw, 500px\" \/><\/p>\n<p><em>\u00a0<\/em><strong>Trusted Palas\u00ae instruments<\/strong><\/p>\n<p>After knowing the outstanding Palas\u00ae instruments in the laboratory, we can also see them at the Christian Albrecht Institute for Pharmaceutical Research at the University of Kiel. The Palas\u00ae Promo\u00ae series is a white-light aerosol measurement system that enables high-resolution temporal analysis of individual particles. Thanks to digital, individual signal processing. The proven T-construction and the advantages of the modular design also allow the welas\u00ae system sensors to utilize flexible new scattering spectra. Which contributes to high resolution, ensuring highly reliable measurement results.<\/p>\n<p>Palas\u00ae equipment and instruments provide reliable data for different monitoring environments. And we will continue to provide peace of mind for research and practical measurements in the future.<\/p>\n<p><strong>Promo\u00ae 3000HP<\/strong><strong> Aerosol Spectrometer<\/strong><\/p>\n<p>Palas\u00ae Promo\u00ae 3000HP aerosol spectrometer is not only resistant to high temperatures and pressures but can also monitor flammable and explosive aerosols. It can also measure particle concentration and size at concentrations up to 10<sup>6<\/sup> p\/cm<sup>3<\/sup>. A dual probe solution is also available, which can be configured for high concentrations (up to 1&#215;10<sup>6<\/sup> p\/cm<sup>3<\/sup>) or low concentrations (down to 1 p\/cm<sup>3<\/sup>) to meet the measurement needs of different concentration areas. At the same time, Palas\u00ae Promo\u00ae 3000HP can be connected to a process control system via various interfaces (USB, Ethernet (LAN), Wi-Fi, RS-232\/485) for system integration.<\/p>\n<p><strong><img loading=\"lazy\" class=\"wp-image-8769\" src=\"https:\/\/palas.com.cn\/en\/wp-content\/uploads\/2023\/05\/4-1.jpg\" alt=\"\" width=\"500\" height=\"420\" srcset=\"https:\/\/palas.com.cn\/en\/wp-content\/uploads\/2023\/05\/4-1.jpg 841w, https:\/\/palas.com.cn\/en\/wp-content\/uploads\/2023\/05\/4-1-300x252.jpg 300w, https:\/\/palas.com.cn\/en\/wp-content\/uploads\/2023\/05\/4-1-768x646.jpg 768w, https:\/\/palas.com.cn\/en\/wp-content\/uploads\/2023\/05\/4-1-24x20.jpg 24w, https:\/\/palas.com.cn\/en\/wp-content\/uploads\/2023\/05\/4-1-36x30.jpg 36w, https:\/\/palas.com.cn\/en\/wp-content\/uploads\/2023\/05\/4-1-48x40.jpg 48w, https:\/\/palas.com.cn\/en\/wp-content\/uploads\/2023\/05\/4-1-600x504.jpg 600w\" sizes=\"(max-width: 500px) 100vw, 500px\" \/><\/strong><\/p>\n<p><strong>Advantages<br \/>\n<\/strong>\u00b7\u00a0 \u00a0Measuring range of 0.2 to 100 \u00b5m (4 measuring ranges selectable in one device)<br \/>\n\u00b7\u00a0 \u00a0Up to four measuring ranges in only one device:<br \/>\n\u2013\u00a0 \u00a00,2 \u00b5m \u2013 10 \u00b5m<br \/>\n\u2013\u00a0 \u00a00,3 \u00b5m \u2013 17 \u00b5m<br \/>\n\u2013\u00a0 \u00a00,6 \u00b5m \u2013 40 \u00b5m<br \/>\n\u2013\u00a0 \u00a02 \u00b5m \u2013 100 \u00b5m (additionally for sensors 2300 and 2500)<br \/>\n\u00b7\u00a0 \u00a0Up to 128 size channels per measuring range<br \/>\n\u00b7\u00a0 \u00a0Concentration range of 1 particle\/cm<sup>3<\/sup> to 10<sup>6<\/sup>particles\/cm<sup>3<\/sup><br \/>\n\u00b7\u00a0 \u00a0Calibration curves for different refractive indices<br \/>\n\u00b7\u00a0 \u00a0Very high and reproducible counting efficiency rate starting at 0.2 \u00b5m<br \/>\n\u00b7\u00a0 \u00a0Optical fiber technology<br \/>\n\u00b7\u00a0 \u00a0Simple operation with a large touch display<br \/>\n\u00b7\u00a0 \u00a0Calibration, cleaning and lamp replacement can all be performed independently by the customer<br \/>\n\u00b7\u00a0 \u00a0External control by RS 232 or Ethernet<br \/>\n\u00b7\u00a0 \u00a0With analysis software PDAnalyze<br \/>\n\u00b7\u00a0 \u00a0Optional: Software PDControl for operation as Welas\u00ae digital available<br \/>\n\u00b7\u00a0 \u00a0Low maintenance<br \/>\n\u00b7\u00a0 \u00a0Reliable function<br \/>\n\u00b7\u00a0 \u00a0Reduces your operating expenses<\/p>\n<p><strong>Applications<br \/>\n<\/strong>\u00b7\u00a0 \u00a0Emission monitoring of installations<br \/>\n\u00b7\u00a0 \u00a0Control of grinding and classification processes<br \/>\n\u00b7\u00a0 \u00a0Monitoring of production processes in the food, pharmaceuticals and chemicals industries<br \/>\n\u00b7\u00a0 \u00a0Testing of complete filters, inertial and wet separators or electrostatic precipitators<\/p>\n<p>(Source of information and some pictures: Sitacuisses &#8211; Own work, CC BY-SA 3.0 de)<\/p>\n<p>Palas\u00ae organizes a series of webinars on various topics to share professional knowledge of aerosol measurement technology. Palas\u00ae technical experts and industry scholars from all over the world will give you detailed online explanations. Welcome to register to attend and learn more about the webinars as soon as possible!<\/p>\n<p><strong>Topic: Study on aerosol concentration and particle size distribution<br \/>\n<\/strong><strong>Time: Friday, June 2, 2023 15: 00 &#8211; 16: 00<\/strong><\/p>\n<p><strong>Speaker: Mr. Jeff Yi<br \/>\nMarket Manager of Industry &amp; Science at Palas\u00ae China<\/strong><\/p>\n<p>You are welcome to register for the conference!<br \/>\n<strong><a href=\"https:\/\/meeting.tencent.com\/dw\/01jMSNrdAR1V\">Click here<\/a> to register<\/strong><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Palas\u00ae Promo\u00ae 3000HP helps the Forschungszentrum Karlsruhe meet the challenges of gas cleaning procedure in the \u201cbiofuel\u201d project<\/p>\n","protected":false},"author":2,"featured_media":8766,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":[],"categories":[376],"tags":[],"_links":{"self":[{"href":"https:\/\/palas.com.cn\/en\/wp-json\/wp\/v2\/posts\/8765"}],"collection":[{"href":"https:\/\/palas.com.cn\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/palas.com.cn\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/palas.com.cn\/en\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/palas.com.cn\/en\/wp-json\/wp\/v2\/comments?post=8765"}],"version-history":[{"count":4,"href":"https:\/\/palas.com.cn\/en\/wp-json\/wp\/v2\/posts\/8765\/revisions"}],"predecessor-version":[{"id":8793,"href":"https:\/\/palas.com.cn\/en\/wp-json\/wp\/v2\/posts\/8765\/revisions\/8793"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/palas.com.cn\/en\/wp-json\/wp\/v2\/media\/8766"}],"wp:attachment":[{"href":"https:\/\/palas.com.cn\/en\/wp-json\/wp\/v2\/media?parent=8765"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/palas.com.cn\/en\/wp-json\/wp\/v2\/categories?post=8765"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/palas.com.cn\/en\/wp-json\/wp\/v2\/tags?post=8765"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}