{"id":8828,"date":"2023-05-29T17:54:25","date_gmt":"2023-05-29T09:54:25","guid":{"rendered":"https:\/\/palas.com.cn\/en\/?p=8828"},"modified":"2023-05-29T17:58:49","modified_gmt":"2023-05-29T09:58:49","slug":"news-2023-05-26-2","status":"publish","type":"post","link":"https:\/\/palas.com.cn\/en\/news-2023-05-26-2\/","title":{"rendered":"Three Advantages Help The Nonwovens Institute at NC State University Choose Palas\u00ae MFP 3000"},"content":{"rendered":"<p>Fibrous nonwoven filters are widely used for various air filtration applications. The double-layer composite filter media usually consists of a coarse and a fine layer. The coarse filter media could capture large particles and extend the lifetime of the composite filters, so it is essential to study coarse filter media.<\/p>\n<p>The Nonwovens Institute at NC State University used Palas\u00ae MFP 3000 for a research project on fibrous nonwoven coarse filters. The MFP 3000 has a high dust concentration test capability as well as flexible and powerful test functions. MFP 3000 assists the team in achieving consistent monitoring data by measuring samples of dust-containing filter media in different stages.<\/p>\n<p><img loading=\"lazy\" class=\"wp-image-8830\" src=\"https:\/\/palas.com.cn\/en\/wp-content\/uploads\/2023\/05\/1-4.jpg\" alt=\"\" width=\"500\" height=\"380\" srcset=\"https:\/\/palas.com.cn\/en\/wp-content\/uploads\/2023\/05\/1-4.jpg 793w, https:\/\/palas.com.cn\/en\/wp-content\/uploads\/2023\/05\/1-4-300x228.jpg 300w, https:\/\/palas.com.cn\/en\/wp-content\/uploads\/2023\/05\/1-4-768x583.jpg 768w, https:\/\/palas.com.cn\/en\/wp-content\/uploads\/2023\/05\/1-4-24x18.jpg 24w, https:\/\/palas.com.cn\/en\/wp-content\/uploads\/2023\/05\/1-4-36x27.jpg 36w, https:\/\/palas.com.cn\/en\/wp-content\/uploads\/2023\/05\/1-4-48x36.jpg 48w, https:\/\/palas.com.cn\/en\/wp-content\/uploads\/2023\/05\/1-4-600x455.jpg 600w\" sizes=\"(max-width: 500px) 100vw, 500px\" \/><\/p>\n<p><em>The Nonwovens Institute at NC State University<\/em><\/p>\n<p><strong>Research teams face measurement challenges<\/strong><\/p>\n<p>Eunkyoung Shim, Associate Professor at The Nonwovens Institute at NC State University, and his Ph.D. student Yu Song conducted this research. They have prepared a fibrous nonwoven coarse filter composed of polypropylene (PP) and binder fiber with a blend ratio of 70:30. However, due to the lack of non-invasive and non-destructive structural characterization techniques, the research progress on the filtration performance and structure evolution of fluffy coarse fiber filter materials during loading is very limited. So they urgently needed a suitable filter media filtration performance test rig.<\/p>\n<p>The test media for coarse filtration materials is usually ISO A2 fine dust with a mass concentration of up to 1,000 mg\/m<sup>3<\/sup>. It is very challenging to measure particles accurately under such high mass concentrations. After investigation, common particle measurement devices in filtration performance testing systems require a dilution system to measure particles. The dilution systems could not be recovered well for large particle sizes (e.g., 3 \u03bcm and above); therefore, the results can vary significantly from the actual situation.<\/p>\n<p>Palas\u00ae MFP 3000 is a widespread measurement system and has been well-received by university research teams. The Nonwovens Institute at NC State University also investigated the test system. They found that the white light source-based particle size spectrometer Promo\u00ae 3000 used in the MFP 3000 can accurately measure fine dust up to 1000 mg\/m<sup>3<\/sup> in A2 as well as coarse dust up to 5,000 mg\/m<sup>3<\/sup> in A4 without the need for a dilution system. This feature was of great interest to the researchers. The flexible test procedure allows the user to load the filter media with dust at a specific differential pressure.<\/p>\n<p>Reliable data is essential for convincing conclusions, and the tests according to the conditions required by the standard makes the results more comparable. Palas\u00ae MFP 3000, which followed ISO 5011, meets the requirements of The Nonwovens Institute at NC State University in terms of testing standards, and it helps to analyze the loading behaviors of the studied fibrous nonwoven coarse filter media.<\/p>\n<p><strong>Test results of the Palas\u00ae MFP 3000<\/strong><\/p>\n<p>In this study, the researchers completed the preparation and then measured and characterized its grammage, thickness, and fiber volume percentage. Palas\u00ae MFP 3000 was then used to measure the dynamic changes in pressure drop and filtration efficiency during the dust loading process. The results of the study are shown in the three data plots below.<\/p>\n<p><img loading=\"lazy\" class=\"wp-image-8831\" src=\"https:\/\/palas.com.cn\/en\/wp-content\/uploads\/2023\/05\/2-2.png\" alt=\"\" width=\"500\" height=\"266\" srcset=\"https:\/\/palas.com.cn\/en\/wp-content\/uploads\/2023\/05\/2-2.png 1078w, https:\/\/palas.com.cn\/en\/wp-content\/uploads\/2023\/05\/2-2-300x160.png 300w, https:\/\/palas.com.cn\/en\/wp-content\/uploads\/2023\/05\/2-2-1024x545.png 1024w, https:\/\/palas.com.cn\/en\/wp-content\/uploads\/2023\/05\/2-2-768x409.png 768w, https:\/\/palas.com.cn\/en\/wp-content\/uploads\/2023\/05\/2-2-24x13.png 24w, https:\/\/palas.com.cn\/en\/wp-content\/uploads\/2023\/05\/2-2-36x19.png 36w, https:\/\/palas.com.cn\/en\/wp-content\/uploads\/2023\/05\/2-2-48x26.png 48w, https:\/\/palas.com.cn\/en\/wp-content\/uploads\/2023\/05\/2-2-600x319.png 600w\" sizes=\"(max-width: 500px) 100vw, 500px\" \/><\/p>\n<p><em>Figure\u00a0a. Pressure drop vs. loaded mass.<\/em><\/p>\n<p>&nbsp;<\/p>\n<p><em><img loading=\"lazy\" class=\"wp-image-8832\" src=\"https:\/\/palas.com.cn\/en\/wp-content\/uploads\/2023\/05\/3-2.png\" alt=\"\" width=\"500\" height=\"434\" srcset=\"https:\/\/palas.com.cn\/en\/wp-content\/uploads\/2023\/05\/3-2.png 814w, https:\/\/palas.com.cn\/en\/wp-content\/uploads\/2023\/05\/3-2-300x260.png 300w, https:\/\/palas.com.cn\/en\/wp-content\/uploads\/2023\/05\/3-2-768x666.png 768w, https:\/\/palas.com.cn\/en\/wp-content\/uploads\/2023\/05\/3-2-24x21.png 24w, https:\/\/palas.com.cn\/en\/wp-content\/uploads\/2023\/05\/3-2-36x31.png 36w, https:\/\/palas.com.cn\/en\/wp-content\/uploads\/2023\/05\/3-2-48x42.png 48w, https:\/\/palas.com.cn\/en\/wp-content\/uploads\/2023\/05\/3-2-600x520.png 600w\" sizes=\"(max-width: 500px) 100vw, 500px\" \/><\/em><\/p>\n<p><em>Figure b. Filtration efficiency vs. loaded mass.<\/em><\/p>\n<p><img loading=\"lazy\" class=\"wp-image-8833\" src=\"https:\/\/palas.com.cn\/en\/wp-content\/uploads\/2023\/05\/4-1.png\" alt=\"\" width=\"500\" height=\"417\" srcset=\"https:\/\/palas.com.cn\/en\/wp-content\/uploads\/2023\/05\/4-1.png 793w, https:\/\/palas.com.cn\/en\/wp-content\/uploads\/2023\/05\/4-1-300x250.png 300w, https:\/\/palas.com.cn\/en\/wp-content\/uploads\/2023\/05\/4-1-768x640.png 768w, https:\/\/palas.com.cn\/en\/wp-content\/uploads\/2023\/05\/4-1-24x20.png 24w, https:\/\/palas.com.cn\/en\/wp-content\/uploads\/2023\/05\/4-1-36x30.png 36w, https:\/\/palas.com.cn\/en\/wp-content\/uploads\/2023\/05\/4-1-48x40.png 48w, https:\/\/palas.com.cn\/en\/wp-content\/uploads\/2023\/05\/4-1-600x500.png 600w\" sizes=\"(max-width: 500px) 100vw, 500px\" \/><\/p>\n<p><em>Figure\u00a0c. Fractional efficiency vs. particle size at various loading stages.<\/em><\/p>\n<p>Figure a. shows that the pressure drop tends to increase with dust loading over time and exhibits an initial slow increase with a subsequent increase in speed. Figure b. shows that both the quantitative and qualitative efficiencies of filtration increase with dust loading and the counting efficiency is much lower than the mass efficiency. The main reason is that the weight of large particle size in the mass concentration share is much greater than that of small particle size, which is more easily filtered. Figure c. shows the change in classification efficiency trend during the step-by-step dust loading.<\/p>\n<p>Palas\u00ae MFP 3000 could measure the dynamic change of pressure drop and filtration efficiency during continuous dust loading. The observation of the coarse filter also provides a solid basis for subsequent studies of the clogging process of the fibrous nonwoven coarse filter. Palas\u00ae knowledge and expertise, the focus on supporting research, and the view of industry standards add significant value to Palas\u00ae MFP 3000, and it received technical and data support for experiments at The Nonwovens Institute at NC State University. Palas\u00ae team will continue to provide strong support for research into efficient media filtration.<\/p>\n<p><strong>Palas\u00ae MFP 3000 filter media filtration performance test rig<\/strong><\/p>\n<p>Palas\u00ae MFP 3000 can be used for five major items of common filter media filtration performance testing:<br \/>\n1.Pressure drop curve<br \/>\n2.Initial fractional efficiency<br \/>\n3.Fractional efficiency during dust loading<br \/>\n4.Dust holding capacity<br \/>\n5.Gravimetric filtration efficiency<\/p>\n<p>The test system also supports testing capabilities for multiple standards. Including but not limited to ISO 5011, ISO 11155-1, DIN 71460-1, ISO 16890, ASHRAE 52.2, and EN 779, for testing the filtration performance of dust, oil, or salt particles according to different standards.<\/p>\n<p><img loading=\"lazy\" class=\"wp-image-8834 size-full\" src=\"https:\/\/palas.com.cn\/en\/wp-content\/uploads\/2023\/05\/5-1.png\" alt=\"\" width=\"272\" height=\"616\" srcset=\"https:\/\/palas.com.cn\/en\/wp-content\/uploads\/2023\/05\/5-1.png 272w, https:\/\/palas.com.cn\/en\/wp-content\/uploads\/2023\/05\/5-1-132x300.png 132w, https:\/\/palas.com.cn\/en\/wp-content\/uploads\/2023\/05\/5-1-11x24.png 11w, https:\/\/palas.com.cn\/en\/wp-content\/uploads\/2023\/05\/5-1-16x36.png 16w, https:\/\/palas.com.cn\/en\/wp-content\/uploads\/2023\/05\/5-1-21x48.png 21w\" sizes=\"(max-width: 272px) 100vw, 272px\" \/><br \/>\n<strong><br \/>\nAdvantages<br \/>\n<\/strong>\u00b7\u00a0 \u00a0Virtually simultaneous measurement of upstream and downstream particle<br \/>\n\u00b7\u00a0 \u00a0Particle size measurements from 0.2 \u2013 40 \u00b5m<br \/>\n\u00b7\u00a0 \u00a0Measurement of Cn max= 10<sup>6<\/sup> particles\/cm<sup>3<\/sup> without dilution<br \/>\n\u00b7\u00a0 \u00a0Internationally comparable measurement results<br \/>\n\u00b7\u00a0 \u00a0Widespread distribution of the measurement system<br \/>\n\u00b7\u00a0 \u00a0High reproducibility of the testing method<br \/>\n\u00b7\u00a0 \u00a0Easy use of different test aerosols, e.g., SAE Fine and Coarse, NaCl\/KCl, DEHS<br \/>\n\u00b7\u00a0 \u00a0Highest raw gas concentrations of up to &gt; 1000 mg\/m3 (ISO Fine) or &gt; 5000 mg\/m3 (ISO Coarse) with measurement of the fraction separation efficiency for burden tests<br \/>\n\u00b7\u00a0 \u00a0Faster filtration efficiency testing in the process<br \/>\n\u00b7\u00a0 \u00a0Flexible filter test software FTControl<br \/>\n\u00b7\u00a0 \u00a0Provide the corresponding test process for different test requirements, support the selection of certain processes, and test<br \/>\n\u00b7\u00a0 \u00a0Easy to operate, even untrained personnel can be instructed quickly in the use of the equipment<br \/>\n\u00b7\u00a0 \u00a0Cleaning and calibration can be performed autonomously by the customer<br \/>\n\u00b7\u00a0 \u00a0The core products used in the test rig (e.g., generators, particle size spectrometers, etc.) can be disassembled and used for other applications<br \/>\n\u00b7\u00a0 \u00a0Provide functional verification reports for individual devices and complete test rig before equipment delivery<br \/>\n\u00b7\u00a0 \u00a0Low maintenance<\/p>\n<p><strong>Applications<br \/>\n<\/strong>\u00b7\u00a0 \u00a0Flat filter media or small filter<br \/>\n\u00b7\u00a0 \u00a0Product development and production quality management<br \/>\n\u00b7\u00a0 \u00a0Tested according to ISO 11155-1 and DIN 71460-1 standards; see MFP 3000 C test rig<br \/>\n\u00b7\u00a0 \u00a0Tested according to ISO 5011; see MFP 3000 M test rig<br \/>\n\u00b7\u00a0 \u00a0Tested according to ISO 16890 and ASHRAE 52.2 standards; see MFP 3000 G test rig<br \/>\n\u00b7\u00a0 \u00a0Tested according to EN 1822-3 and ISO 29463-3 standards; see MFP Nano Plus 4000 test rig<br \/>\n\u00b7\u00a0 \u00a0Other standard or customer-defined test requirements<br \/>\n\u00b7\u00a0 \u00a0Automatic measurement of graded filtration efficiency, pressure drop curve, dust holding capacity, and gravimetric filtration efficiency<br \/>\n\u00b7\u00a0 \u00a0Product quality control and comparison between users and upstream and downstream enterprises<\/p>\n<p>Palas\u00ae organizes a series of webinars on various topics to share professional knowledge of aerosol measurement technology. Palas\u00ae technical experts and industry scholars from all over the world will give you detailed online explanations. You are welcome to register to attend and learn more about the webinars as soon as possible!<\/p>\n<p><strong>Topic: Study on aerosol concentration and particle size distribution<\/strong><\/p>\n<p><strong>Time: Friday, June 2, 2023, 15: 00 &#8211; 16: 00<br \/>\n<\/strong><strong><br \/>\nSpeaker: Mr. Jeff Yi<br \/>\nMarket Manager of Industry &amp; Science at Palas\u00ae China<\/strong><\/p>\n<p>You are welcome to register for the conference!<br \/>\n<strong><a href=\"https:\/\/meeting.tencent.com\/dw\/01jMSNrdAR1V\">Click here<\/a> to register<\/strong><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Palas\u00ae MFP 3000 filter media filtration performance test rig provides filtration data for research at The Nonwovens Institute at NC State University<\/p>\n","protected":false},"author":2,"featured_media":8829,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":[],"categories":[376],"tags":[],"_links":{"self":[{"href":"https:\/\/palas.com.cn\/en\/wp-json\/wp\/v2\/posts\/8828"}],"collection":[{"href":"https:\/\/palas.com.cn\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/palas.com.cn\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/palas.com.cn\/en\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/palas.com.cn\/en\/wp-json\/wp\/v2\/comments?post=8828"}],"version-history":[{"count":2,"href":"https:\/\/palas.com.cn\/en\/wp-json\/wp\/v2\/posts\/8828\/revisions"}],"predecessor-version":[{"id":8836,"href":"https:\/\/palas.com.cn\/en\/wp-json\/wp\/v2\/posts\/8828\/revisions\/8836"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/palas.com.cn\/en\/wp-json\/wp\/v2\/media\/8829"}],"wp:attachment":[{"href":"https:\/\/palas.com.cn\/en\/wp-json\/wp\/v2\/media?parent=8828"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/palas.com.cn\/en\/wp-json\/wp\/v2\/categories?post=8828"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/palas.com.cn\/en\/wp-json\/wp\/v2\/tags?post=8828"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}