{"id":4242,"date":"2020-07-23T05:39:04","date_gmt":"2020-07-23T05:39:04","guid":{"rendered":"https:\/\/palas-china.com.cn\/en\/?post_type=product&#038;p=4242"},"modified":"2025-01-17T14:54:16","modified_gmt":"2025-01-17T06:54:16","slug":"dc-10000","status":"publish","type":"product","link":"https:\/\/palas.com.cn\/en\/product\/dc-10000\/","title":{"rendered":"DC 10000"},"content":{"rendered":"<p>[vc_row][vc_column][vc_column_text]The DC 10000 consists of four cascaded special dilution systems with the dilution factor 1:10. The DC 10000 dilution cascade has one aerosol inlet and four aerosol outlets. Depending on which aerosol outlet is connected to the measuring device, the aerosol with the dilution factors 1:10, 1:100, 1:1,000 or 1:10,000 are diluted and measured.<\/p>\n<p>The DC 10000 can be operated with all common optical particle counters (OPC) according to ISO 12501-4 or optical aerosol spectrometers (OAS) according to ISO 12501-1. The DC 10000 can be used up to a particle size of approx. 5 \u00b5m.<\/p>\n<p><a class=\"vfsfile image block fancybox\" title=\"\" href=\"https:\/\/www.palas.de\/file\/jh1878\/image\/jpeg\/DC+10000+Bild+Englisch.JPG.jpg?size=1200x700\" name=\"vfsfilejh1878\" data-fancybox-group=\"fancybox-d9bc0d2555dedb3295599f2ec8f36b6f\"><img loading=\"lazy\" class=\"alignnone size-medium wp-image-4243\" src=\"https:\/\/palas-china.com.cn\/en\/wp-content\/uploads\/2020\/07\/1-38-208x300.jpg\" alt=\"\" width=\"208\" height=\"300\" srcset=\"https:\/\/palas.com.cn\/en\/wp-content\/uploads\/2020\/07\/1-38-208x300.jpg 208w, https:\/\/palas.com.cn\/en\/wp-content\/uploads\/2020\/07\/1-38.jpg 485w\" sizes=\"(max-width: 208px) 100vw, 208px\" \/><\/a><\/p>\n<p>Fig. 1: Overview of the DC 10000, front view<\/p>\n<p><b>Functional principle<\/b><\/p>\n<p><a class=\"vfsfile image block fancybox\" title=\"\" href=\"https:\/\/www.palas.de\/file\/dQ2047\/image\/jpeg\/VKL+10+Principle_eng.JPG.jpg?size=1200x700\" name=\"vfsfiledQ2047\" data-fancybox-group=\"fancybox-d9bc0d2555dedb3295599f2ec8f36b6f\"><img loading=\"lazy\" class=\"alignnone size-medium wp-image-4244\" src=\"https:\/\/palas-china.com.cn\/en\/wp-content\/uploads\/2020\/07\/2-26-300x173.jpg\" alt=\"\" width=\"300\" height=\"173\" srcset=\"https:\/\/palas.com.cn\/en\/wp-content\/uploads\/2020\/07\/2-26-300x173.jpg 300w, https:\/\/palas.com.cn\/en\/wp-content\/uploads\/2020\/07\/2-26-1024x591.jpg 1024w, https:\/\/palas.com.cn\/en\/wp-content\/uploads\/2020\/07\/2-26-768x443.jpg 768w, https:\/\/palas.com.cn\/en\/wp-content\/uploads\/2020\/07\/2-26-600x346.jpg 600w, https:\/\/palas.com.cn\/en\/wp-content\/uploads\/2020\/07\/2-26.jpg 1200w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><\/a><\/p>\n<p>Fig. 2: Functional principle<\/p>\n<p>Particle-free air with the volume flow V<sub>R\u00a0<\/sub>circulates through an annular passage around the suction nozzle. Thus, according to Bernoulli, a volume flow V<sub>An<\/sub>\u00a0is generated in the suction nozzle.<\/p>\n<p>The dilution factor V<sub>F<\/sub>\u00a0is calculated according to the formula:<\/p>\n<p><a class=\"vfsfile image block fancybox\" title=\"\" href=\"https:\/\/www.palas.de\/file\/mx1143\/image\/jpeg\/Verd%C3%BCnnungssysteme+Formel.JPG.jpg?size=1200x700\" name=\"vfsfilemx1143\" data-fancybox-group=\"fancybox-d9bc0d2555dedb3295599f2ec8f36b6f\"><img loading=\"lazy\" class=\"alignnone size-medium wp-image-4245\" src=\"https:\/\/palas-china.com.cn\/en\/wp-content\/uploads\/2020\/07\/3-19-300x152.jpg\" alt=\"\" width=\"300\" height=\"152\" srcset=\"https:\/\/palas.com.cn\/en\/wp-content\/uploads\/2020\/07\/3-19-300x152.jpg 300w, https:\/\/palas.com.cn\/en\/wp-content\/uploads\/2020\/07\/3-19-1024x520.jpg 1024w, https:\/\/palas.com.cn\/en\/wp-content\/uploads\/2020\/07\/3-19-768x390.jpg 768w, https:\/\/palas.com.cn\/en\/wp-content\/uploads\/2020\/07\/3-19-600x305.jpg 600w, https:\/\/palas.com.cn\/en\/wp-content\/uploads\/2020\/07\/3-19.jpg 1200w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><\/a><\/p>\n<p>Fig. 3: Formula for the dilution factor V<sub>F<\/sub>.<\/p>\n<p>The DC 10000 needs no compressed air connection. So only an electrical power supply is necessary for operation.<\/p>\n<p><a class=\"vfsfile image block fancybox\" title=\"\" href=\"https:\/\/www.palas.de\/file\/FC1999\/image\/jpeg\/characteristics+dilution+systems.JPG.jpg?size=1200x700\" name=\"vfsfileFC1999\" data-fancybox-group=\"fancybox-d9bc0d2555dedb3295599f2ec8f36b6f\"><img loading=\"lazy\" class=\"alignnone size-medium wp-image-4246\" src=\"https:\/\/palas-china.com.cn\/en\/wp-content\/uploads\/2020\/07\/4-4-300x155.jpg\" alt=\"\" width=\"300\" height=\"155\" srcset=\"https:\/\/palas.com.cn\/en\/wp-content\/uploads\/2020\/07\/4-4-300x155.jpg 300w, https:\/\/palas.com.cn\/en\/wp-content\/uploads\/2020\/07\/4-4-1024x528.jpg 1024w, https:\/\/palas.com.cn\/en\/wp-content\/uploads\/2020\/07\/4-4-768x396.jpg 768w, https:\/\/palas.com.cn\/en\/wp-content\/uploads\/2020\/07\/4-4-600x310.jpg 600w, https:\/\/palas.com.cn\/en\/wp-content\/uploads\/2020\/07\/4-4.jpg 1200w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><\/a><\/p>\n<p>Table 1:\u00a0 Technical characteristics of Palas<sup>\u00ae<\/sup>\u00a0dilution systems[\/vc_column_text][\/vc_column][\/vc_row]<\/p>\n","protected":false},"excerpt":{"rendered":"<p>DC 10000 dilution cascade with electrical operating pump<\/p>\n","protected":false},"featured_media":4260,"template":"","meta":[],"_links":{"self":[{"href":"https:\/\/palas.com.cn\/en\/wp-json\/wp\/v2\/product\/4242"}],"collection":[{"href":"https:\/\/palas.com.cn\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/palas.com.cn\/en\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/palas.com.cn\/en\/wp-json\/wp\/v2\/media\/4260"}],"wp:attachment":[{"href":"https:\/\/palas.com.cn\/en\/wp-json\/wp\/v2\/media?parent=4242"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}