{"id":4592,"date":"2020-07-29T06:14:30","date_gmt":"2020-07-29T06:14:30","guid":{"rendered":"https:\/\/palas-china.com.cn\/en\/?post_type=product&#038;p=4592"},"modified":"2025-01-20T12:36:02","modified_gmt":"2025-01-20T04:36:02","slug":"aerosol-sensor-welas-1200","status":"publish","type":"product","link":"https:\/\/palas.com.cn\/en\/product\/aerosol-sensor-welas-1200\/","title":{"rendered":"Aerosol sensor welas\u00ae 1200"},"content":{"rendered":"<p>[vc_row][vc_column][vc_column_text]The model 1200 aerosol sensors are equipped with a small measurement volume and are used for coincidence-free measurement with a maximum number concentrations up to 50,000 particles\/cm<sup>3\u00a0<\/sup>.<\/p>\n<p>Measuring range: 0.12 \u2013 3.5 \u00b5m \/ 0.2 \u2013 10 \u00b5m \/ 0.3 \u2013 17 \u00b5m \/ 0.6 \u2013 40 \u00b5m.<\/p>\n<p><b>Functional principle:<\/b><\/p>\n<p>welas<sup>\u00ae<\/sup>\u00a0digital and Promo<sup>\u00ae\u00a0<\/sup>digital are based on scattered-light analysis on a single particle. The particles to be measured pass through a T-shaped, optically delineated measuring volume that is illuminated by a white light source. This generates a scattered-light pulse whose level is a measure for the concentration.<\/p>\n<p><b>The high size classification accuracy and the high size resolution are guaranteed by the following special feature:<\/b><\/p>\n<p><span style=\"color: #008b57;\">\u2022<\/span>\u00a0\u00a0\u00a0\u00a0White light and 90\u00b0 light-scattering detection<br \/>\n<b>\u21d2<\/b>\u00a0<b>unambiguous calibration curve<\/b><br \/>\n<span style=\"color: #008b57;\">\u2022<\/span>\u00a0\u00a0\u00a0\u00a0Patented T-aperture technology for a T-shaped measurement technology<br \/>\n<b>\u21d2<\/b>\u00a0<b>no border zone error<\/b><br \/>\n<span style=\"color: #008b57;\">\u2022<\/span>\u00a0\u00a0\u00a0\u00a0New digital individual signal processing for the analysis of the scattered-light pulse<br \/>\n<b>\u21d2<\/b>\u00a0<b>coincidence detection and correction which enables measurement in up to 5 times higher concentrations<\/b><\/p>\n<p><b>Example: the welas<sup>\u00ae<\/sup>\u00a0sensor aerosol guide heatable up to 250\u00b0C (see variations)<\/b><\/p>\n<p>Trouble-free and reliable measurement of large particles up to 40 \u00b5m in the sensor is guaranteed by the vertical aerosol duct at a high volume flow of 5 l\/min and a large sampling tube diameter.<\/p>\n<p><b>Size limitation of the optical measuring volume<\/b><\/p>\n<p>The table below shows the theoretical minimum separation of the particles at a given number concentration.<br \/>\nAt a number concentration of 10<sup>3<\/sup>\u00a0per cm<sup>3<\/sup>\u00a0the optical measuring volume must not be larger than 1 mm<sup>3<\/sup>\u00a0.<\/p>\n<p><img loading=\"lazy\" class=\"alignnone size-medium wp-image-4594\" src=\"https:\/\/palas-china.com.cn\/en\/wp-content\/uploads\/2020\/07\/1-47-300x206.jpg\" alt=\"\" width=\"300\" height=\"206\" srcset=\"https:\/\/palas.com.cn\/en\/wp-content\/uploads\/2020\/07\/1-47-300x206.jpg 300w, https:\/\/palas.com.cn\/en\/wp-content\/uploads\/2020\/07\/1-47-768x527.jpg 768w, https:\/\/palas.com.cn\/en\/wp-content\/uploads\/2020\/07\/1-47-24x16.jpg 24w, https:\/\/palas.com.cn\/en\/wp-content\/uploads\/2020\/07\/1-47-36x25.jpg 36w, https:\/\/palas.com.cn\/en\/wp-content\/uploads\/2020\/07\/1-47-48x33.jpg 48w, https:\/\/palas.com.cn\/en\/wp-content\/uploads\/2020\/07\/1-47-600x412.jpg 600w, https:\/\/palas.com.cn\/en\/wp-content\/uploads\/2020\/07\/1-47.jpg 1020w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><\/p>\n<p>The customer can select a sensor with the appropriate measuring volume size depending on the concentration to be measured.<\/p>\n<p><a class=\"vfsfile image block fancybox\" title=\"\" href=\"https:\/\/www.palas.de\/file\/7T1255\/image\/jpeg\/optisches+Messvolumen+welas+Sensoren.jpg.jpg?size=1200x700\" name=\"vfsfile7T1255\" data-fancybox-group=\"fancybox-ef04acd7629d79d82fb01ccd7354cfbf\"><img loading=\"lazy\" class=\"alignnone size-medium wp-image-4595\" src=\"https:\/\/palas-china.com.cn\/en\/wp-content\/uploads\/2020\/07\/2-31-300x252.jpg\" alt=\"\" width=\"300\" height=\"252\" srcset=\"https:\/\/palas.com.cn\/en\/wp-content\/uploads\/2020\/07\/2-31-300x252.jpg 300w, https:\/\/palas.com.cn\/en\/wp-content\/uploads\/2020\/07\/2-31-768x645.jpg 768w, https:\/\/palas.com.cn\/en\/wp-content\/uploads\/2020\/07\/2-31-24x20.jpg 24w, https:\/\/palas.com.cn\/en\/wp-content\/uploads\/2020\/07\/2-31-36x30.jpg 36w, https:\/\/palas.com.cn\/en\/wp-content\/uploads\/2020\/07\/2-31-48x40.jpg 48w, https:\/\/palas.com.cn\/en\/wp-content\/uploads\/2020\/07\/2-31-600x504.jpg 600w, https:\/\/palas.com.cn\/en\/wp-content\/uploads\/2020\/07\/2-31.jpg 833w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><\/a><\/p>\n<p>For concentrations up to 500,000 particles\/cm<sup>3<\/sup>\u00a0the welas<sup>\u00ae<\/sup>\u00a01100 sensor with a very small measuring volume is used. This ensures the smallest measuring volume such that only one particle ever enters the measuring volume. In low concentrations the model welas<sup>\u00ae<\/sup>\u00a01200 with a larger measuring volume offers the advantage of a higher counting rate at the same number concentration.<\/p>\n<p><b>Counting efficiency of the sensors<\/b><br \/>\nThe welas<sup>\u00ae<\/sup>\u00a0sensors are characterized by a particularly good agreement of counting efficiency and particle size resolution.<br \/>\nThis means that the measurement results are highly comparable in terms of the number concentration and particle size measured when using different sensors.<\/p>\n<p><img loading=\"lazy\" class=\"alignnone size-medium wp-image-4596\" src=\"https:\/\/palas-china.com.cn\/en\/wp-content\/uploads\/2020\/07\/3-9-300x166.png\" alt=\"\" width=\"300\" height=\"166\" srcset=\"https:\/\/palas.com.cn\/en\/wp-content\/uploads\/2020\/07\/3-9-300x166.png 300w, https:\/\/palas.com.cn\/en\/wp-content\/uploads\/2020\/07\/3-9-1024x565.png 1024w, https:\/\/palas.com.cn\/en\/wp-content\/uploads\/2020\/07\/3-9-768x424.png 768w, https:\/\/palas.com.cn\/en\/wp-content\/uploads\/2020\/07\/3-9-24x13.png 24w, https:\/\/palas.com.cn\/en\/wp-content\/uploads\/2020\/07\/3-9-36x20.png 36w, https:\/\/palas.com.cn\/en\/wp-content\/uploads\/2020\/07\/3-9-48x26.png 48w, https:\/\/palas.com.cn\/en\/wp-content\/uploads\/2020\/07\/3-9-600x331.png 600w, https:\/\/palas.com.cn\/en\/wp-content\/uploads\/2020\/07\/3-9.png 1200w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><\/p>\n<p>Graph 1:<br \/>\nThe welas<sup>\u00ae<\/sup>\u00a01000 series of aerosol sensors is characterized by its very high counting efficiency starting from 0.12 \u00b5m!<\/p>\n<p><b>Pressure-resistant and heatable aerosol sensors with a special cuvette for the variants P, H and HP<\/b><br \/>\nSpecial measuring cuvettes allow the use of the welas<sup>\u00ae<\/sup>\u00a0aerosol sensors even under unusual measuring conditions. These are available:<\/p>\n<p><span style=\"color: #008b57;\">\u2022<\/span> \u00a0\u00a0\u00a0heatable sensors up to 250\u00b0C; higher temperatures on request<br \/>\n<span style=\"color: #008b57;\">\u2022<\/span> \u00a0\u00a0\u00a0pressure-resistant sensors up to 10 bar overpressure<br \/>\n<span style=\"color: #008b57;\">\u2022<\/span>\u00a0\u00a0\u00a0\u00a0sensors resistant against chemically aggressive media[\/vc_column_text][\/vc_column][\/vc_row]<\/p>\n","protected":false},"excerpt":{"rendered":"<p>welas<sup>\u00ae<\/sup>\u00a01200 aerosol sensor for number concentrations up to 50,000 particles\/cm<sup>3<\/sup><\/p>\n","protected":false},"featured_media":4624,"template":"","meta":[],"_links":{"self":[{"href":"https:\/\/palas.com.cn\/en\/wp-json\/wp\/v2\/product\/4592"}],"collection":[{"href":"https:\/\/palas.com.cn\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/palas.com.cn\/en\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/palas.com.cn\/en\/wp-json\/wp\/v2\/media\/4624"}],"wp:attachment":[{"href":"https:\/\/palas.com.cn\/en\/wp-json\/wp\/v2\/media?parent=4592"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}