{"id":4691,"date":"2020-07-29T11:43:23","date_gmt":"2020-07-29T11:43:23","guid":{"rendered":"https:\/\/palas-china.com.cn\/en\/?post_type=product&#038;p=4691"},"modified":"2020-07-30T04:13:09","modified_gmt":"2020-07-30T04:13:09","slug":"mmtc-2000","status":"publish","type":"product","link":"https:\/\/palas.com.cn\/en\/product\/mmtc-2000\/","title":{"rendered":"MMTC 2000"},"content":{"rendered":"<p>[vc_row][vc_column][vc_column_text]With the MMTC series, Palas<sup>\u00ae<\/sup>\u00a0offers a reliable and cost-effective test system for quality control and the development of cleanable filter media. The filter test rigs in the MMTC series offer high test result reproducibility. The compact and robust layout of the MMTC 2000 and its functional and simple operation have impressed our customers in industry in particular. With the aid of the MMTC series, standard filter media tests can be performed in accordance with VDI 3926 (including aging). Different media are optimized for different applications in terms of their structure and surface treatment. This minimizes emissions and increases the service life of the medium. In contrast to the VDI guidelines, with the aid of the MMTC series it is possible to perform reliable filter media tests with different powders that are actually used in practice. Palas<sup>\u00ae<\/sup>\u00a0MMTC filter test rigs are already used internationally with great success in industry.<\/p>\n<p><b>Test procedure:<\/b><\/p>\n<p>In the test procedure, a test aerosol burden is applied to the test filter. The rise in pressure loss is measured on the test filter. If a defined pressure loss is reached or a predefined time interval is exceeded, the filter medium is cleaned off using a blast of compressed air. These cycles are repeated until the end of the test procedure.<\/p>\n<p><b>Test results:<\/b><\/p>\n<p>In order to compare the different filter media, the following data is collected:<\/p>\n<p><span style=\"color: #008b57;\">\u2022<\/span> \u00a0\u00a0\u00a0The pressure loss curve on the test filter and on the gravimetric end filter<br \/>\n<span style=\"color: #008b57;\">\u2022<\/span> \u00a0\u00a0\u00a0The residual pressure loss curve after cleaning<br \/>\n<span style=\"color: #008b57;\">\u2022<\/span> \u00a0\u00a0\u00a0The mass emission at the gravimetric end filter<br \/>\n<span style=\"color: #008b57;\">\u2022<\/span>\u00a0\u00a0\u00a0\u00a0The particle penetration in the clean gas with Promo<sup>\u00ae<\/sup>\u00a0(optional)<\/p>\n<p><b>Overview of the MMTC 2000:<\/b><\/p>\n<p><a class=\"vfsfile image block fancybox\" title=\"\" href=\"https:\/\/www.palas.de\/file\/sw1194\/image\/jpeg\/MMTC+%C3%9Cbersicht.JPG.jpg?size=1200x700\" name=\"vfsfilesw1194\" data-fancybox-group=\"fancybox-70cbd6774d688380126a7ca21d90a863\"><img loading=\"lazy\" class=\"alignnone size-medium wp-image-4709\" src=\"https:\/\/palas-china.com.cn\/en\/wp-content\/uploads\/2020\/07\/1-56-300x155.jpg\" alt=\"\" width=\"300\" height=\"155\" srcset=\"https:\/\/palas.com.cn\/en\/wp-content\/uploads\/2020\/07\/1-56-300x155.jpg 300w, https:\/\/palas.com.cn\/en\/wp-content\/uploads\/2020\/07\/1-56-1024x529.jpg 1024w, https:\/\/palas.com.cn\/en\/wp-content\/uploads\/2020\/07\/1-56-768x397.jpg 768w, https:\/\/palas.com.cn\/en\/wp-content\/uploads\/2020\/07\/1-56-24x12.jpg 24w, https:\/\/palas.com.cn\/en\/wp-content\/uploads\/2020\/07\/1-56-36x19.jpg 36w, https:\/\/palas.com.cn\/en\/wp-content\/uploads\/2020\/07\/1-56-48x25.jpg 48w, https:\/\/palas.com.cn\/en\/wp-content\/uploads\/2020\/07\/1-56-600x310.jpg 600w, https:\/\/palas.com.cn\/en\/wp-content\/uploads\/2020\/07\/1-56.jpg 1200w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><\/a><\/p>\n<p><b>Dust dispersion with the RBG 2000:<\/b><\/p>\n<p><span style=\"color: #008b57;\">\u2022<\/span>\u00a0\u00a0\u00a0\u00a0Suitable for many different dusts used in real practical applications. The filtration and cleanability properties of surface filter media depend to a very large extent on the properties of the dust being filtered. It is therefore vital that these media can be\u00a0<b>tested with dusts used in real practical applications<\/b>.<br \/>\n<span style=\"color: #008b57;\">\u2022<\/span>\u00a0\u00a0\u00a0\u00a0<b>Automatic control of the dust disperser RBG 2000<\/b>\u00a0via the software of the MMTC 2000. This also offers you a simple way to adjust the mass flow rate.<br \/>\n<span style=\"color: #008b57;\">\u2022<\/span>\u00a0\u00a0\u00a0\u00a0Particularly large dust container for long testing times.<\/p>\n<p><b>Horizontal dust processing unit:<\/b><\/p>\n<p><span style=\"color: #008b57;\">\u2022<\/span> \u00a0\u00a0\u00a0Minimization of particle losses through sedimentation and virtually homogeneous dust distribution on the test filter<br \/>\n<span style=\"color: #008b57;\">\u2022<\/span> \u00a0\u00a0\u00a0Simple adjustment of the raw gas concentration<br \/>\n<span style=\"color: #008b57;\">\u2022<\/span> \u00a0\u00a0\u00a0Re-application of fine dust to the filter after cleaning \u2013 as in practice<br \/>\n<span style=\"color: #008b57;\">\u2022<\/span>\u00a0\u00a0\u00a0\u00a0Only small quantities of dust required<\/p>\n<p><b>Automatic test for leaks:<\/b><\/p>\n<p>Before the start of a filter test, an automatic test can be performed to check its leak-tightness in 3 minutes.<\/p>\n<p><b>Aerosol sampling in the clean gas for online emission measurements with the Promo<sup>\u00ae<\/sup>\u00a0system:<\/b><\/p>\n<p><span style=\"color: #008b57;\">\u2022<\/span> \u00a0\u00a0\u00a0Representative isokinetic sampling<br \/>\n<span style=\"color: #008b57;\">\u2022<\/span> \u00a0\u00a0\u00a0No influence on the cleaning pulse<br \/>\n<span style=\"color: #008b57;\">\u2022<\/span>\u00a0\u00a0\u00a0\u00a0High time resolution of 1 s in order to display the particle penetration during the cleaning pulse<\/p>\n<p><b>MMTC software:<\/b><\/p>\n<p>Windows-based software for controlling the test system, including automatic test procedures and data analysis:<\/p>\n<p><span style=\"color: #008b57;\">\u2022<\/span>\u00a0\u00a0\u00a0\u00a0Standard test method in accordance with VDI 3926 (with aging)<br \/>\n<span style=\"color: #008b57;\">\u2022<\/span>\u00a0\u00a0\u00a0\u00a0Standard test report and data analysis in accordance with VDI 3926<br \/>\n<span style=\"color: #008b57;\">\u2022<\/span>\u00a0\u00a0\u00a0\u00a0Individual adjustment of operating parameters<br \/>\n<span style=\"color: #008b57;\">\u2022<\/span>\u00a0\u00a0\u00a0\u00a0Individual programming of the test method<br \/>\n<span style=\"color: #008b57;\">\u2022<\/span>\u00a0\u00a0\u00a0\u00a0Individual evaluation of the residual pressure loss and cycle time, comparison of individual cycles and representation of the overall test<br \/>\n<span style=\"color: #008b57;\">\u2022<\/span>\u00a0\u00a0\u00a0\u00a0Data export to Excel<\/p>\n<p><b>Simulation of the so-called garland effect:<\/b><\/p>\n<p>In practical applications, the way the medium is prepared and cut to size on the supporting basket influences the cleaning characteristics and dust emissions of a filter. This is referred to as the so-called &#8220;garland effect&#8221;. Palas<sup>\u00ae<\/sup>\u00a0offers adapters with different support devices for the test filter so that this effect can be simulated in the laboratory.<\/p>\n<p><a class=\"vfsfile image block fancybox\" title=\"\" href=\"https:\/\/www.palas.de\/file\/pD1193\/image\/jpeg\/MMTC+Girlandeneffekt.jpg.jpg?size=1200x700\" name=\"vfsfilepD1193\" data-fancybox-group=\"fancybox-70cbd6774d688380126a7ca21d90a863\"><img loading=\"lazy\" class=\"alignnone size-medium wp-image-4710\" src=\"https:\/\/palas-china.com.cn\/en\/wp-content\/uploads\/2020\/07\/2-36-300x118.jpg\" alt=\"\" width=\"300\" height=\"118\" srcset=\"https:\/\/palas.com.cn\/en\/wp-content\/uploads\/2020\/07\/2-36-300x118.jpg 300w, https:\/\/palas.com.cn\/en\/wp-content\/uploads\/2020\/07\/2-36-1024x404.jpg 1024w, https:\/\/palas.com.cn\/en\/wp-content\/uploads\/2020\/07\/2-36-768x303.jpg 768w, https:\/\/palas.com.cn\/en\/wp-content\/uploads\/2020\/07\/2-36-24x9.jpg 24w, https:\/\/palas.com.cn\/en\/wp-content\/uploads\/2020\/07\/2-36-36x14.jpg 36w, https:\/\/palas.com.cn\/en\/wp-content\/uploads\/2020\/07\/2-36-48x19.jpg 48w, https:\/\/palas.com.cn\/en\/wp-content\/uploads\/2020\/07\/2-36-600x237.jpg 600w, https:\/\/palas.com.cn\/en\/wp-content\/uploads\/2020\/07\/2-36.jpg 1199w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><\/a><\/p>\n<p><b>In-situ measurement:<\/b><\/p>\n<p>The simulation of realistic conditions in the laboratory often requires a big investment in terms of time and money. However, thanks to its compact design the MMTC 2000 can be simply attached to a filter housing so that the filter test can be performed under realistic conditions.[\/vc_column_text][\/vc_column][\/vc_row]<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Filter test rig for\u00a0<strong>cleanable filter media in accordance with VDI 3926. Versions for temperatur and\/ or rel. humidity control<\/strong><\/p>\n","protected":false},"featured_media":4725,"template":"","meta":[],"_links":{"self":[{"href":"https:\/\/palas.com.cn\/en\/wp-json\/wp\/v2\/product\/4691"}],"collection":[{"href":"https:\/\/palas.com.cn\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/palas.com.cn\/en\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/palas.com.cn\/en\/wp-json\/wp\/v2\/media\/4725"}],"wp:attachment":[{"href":"https:\/\/palas.com.cn\/en\/wp-json\/wp\/v2\/media?parent=4691"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}