{"id":5376,"date":"2020-08-18T05:51:19","date_gmt":"2020-08-18T05:51:19","guid":{"rendered":"https:\/\/palas-china.com.cn\/en\/?post_type=product&#038;p=5376"},"modified":"2025-01-20T12:16:36","modified_gmt":"2025-01-20T04:16:36","slug":"aerosol-sensor-welas-2070","status":"publish","type":"product","link":"https:\/\/palas.com.cn\/en\/product\/aerosol-sensor-welas-2070\/","title":{"rendered":"Aerosol sensor welas\u00ae 2070"},"content":{"rendered":"<p>The model 2070 aerosol sensors are equipped with a very small measurement volume and are used for coincidence-free measurement with a maximum number concentrations up to 1,000,000 particles\/cm<sup>3<\/sup>\u00a0and in the highest mass concentrations, e.g. Arizona dust A2, SAE Fine, up to 1,000 mg\/m<sup>3<\/sup>\u00a0.<\/p>\n<p>Measuring range: 0.2 \u2013 10 \u00b5m \/ 0.3 \u2013 17 \u00b5m \/ 0.6 \u2013 40 \u00b5m.<\/p>\n<p><b>Functional principle:<\/b><br \/>\nwelas<sup>\u00ae<\/sup>\u00a0digital and Promo<sup>\u00ae<\/sup>\u00a0digital are based on scattered-light analysis on a single particle. The particles to be measured pass through a T-shaped, optically delineated measuring volume that is illuminated by a white light source. This generates a scattered-light pulse whose level is a measure for the concentration.<\/p>\n<p><b>The high size classification accuracy and the high size resolution are guaranteed by the following special feature:<\/b><\/p>\n<p><span style=\"color: #008b57;\">\u2022<\/span>\u00a0\u00a0\u00a0\u00a0White light and 90\u00b0 light-scattering detection<br \/>\n\u2192\u00a0<b>unambiguous calibration curve<br \/>\n<\/b><span style=\"color: #008b57;\">\u2022<\/span>\u00a0\u00a0\u00a0\u00a0Patented T-aperture technology for a T-shaped measurement technology<br \/>\n\u2192\u00a0<b>no border zone error<br \/>\n<\/b><span style=\"color: #008b57;\">\u2022<\/span>\u00a0\u00a0\u00a0\u00a0New digital individual signal processing for the analysis of the scattered-light pulse<br \/>\n\u2192<b>\u00a0coincidence detection and correction which enables measurement in up to 5 times higher concentrations<\/b><\/p>\n<p><b>Example: the welas<sup>\u00ae<\/sup>\u00a0sensor aerosol guide heatable up to 250\u00b0C (see variations)<\/b><\/p>\n<p>Trouble-free and reliable measurement of large particles up to 40 \u00b5m in the sensor is guaranteed by the vertical aerosol duct at a high volume flow of 5 l\/min and a large sampling tube diameter.<\/p>\n<p><b><img loading=\"lazy\" class=\"alignnone size-medium wp-image-5378\" src=\"https:\/\/palas-china.com.cn\/en\/wp-content\/uploads\/2020\/08\/1-19-300x177.jpg\" alt=\"\" width=\"300\" height=\"177\" srcset=\"https:\/\/palas.com.cn\/en\/wp-content\/uploads\/2020\/08\/1-19-300x177.jpg 300w, https:\/\/palas.com.cn\/en\/wp-content\/uploads\/2020\/08\/1-19-1024x605.jpg 1024w, https:\/\/palas.com.cn\/en\/wp-content\/uploads\/2020\/08\/1-19-768x454.jpg 768w, https:\/\/palas.com.cn\/en\/wp-content\/uploads\/2020\/08\/1-19-24x14.jpg 24w, https:\/\/palas.com.cn\/en\/wp-content\/uploads\/2020\/08\/1-19-36x21.jpg 36w, https:\/\/palas.com.cn\/en\/wp-content\/uploads\/2020\/08\/1-19-48x28.jpg 48w, https:\/\/palas.com.cn\/en\/wp-content\/uploads\/2020\/08\/1-19-600x354.jpg 600w, https:\/\/palas.com.cn\/en\/wp-content\/uploads\/2020\/08\/1-19.jpg 1185w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><br \/>\nSize limitation of the optical measuring volume<\/b><\/p>\n<p>The table below shows the theoretical minimum separation of the particles at a given number concentration. At a number concentration of 10<sup>3<\/sup>\u00a0per cm<sup>3<\/sup>\u00a0the optical measuring volume must not be larger than 1 mm<sup>3<\/sup>\u00a0.<\/p>\n<p><img loading=\"lazy\" class=\"alignnone size-medium wp-image-5379\" src=\"https:\/\/palas-china.com.cn\/en\/wp-content\/uploads\/2020\/08\/2-15-300x206.jpg\" alt=\"\" width=\"300\" height=\"206\" srcset=\"https:\/\/palas.com.cn\/en\/wp-content\/uploads\/2020\/08\/2-15-300x206.jpg 300w, https:\/\/palas.com.cn\/en\/wp-content\/uploads\/2020\/08\/2-15-768x527.jpg 768w, https:\/\/palas.com.cn\/en\/wp-content\/uploads\/2020\/08\/2-15-24x16.jpg 24w, https:\/\/palas.com.cn\/en\/wp-content\/uploads\/2020\/08\/2-15-36x25.jpg 36w, https:\/\/palas.com.cn\/en\/wp-content\/uploads\/2020\/08\/2-15-48x33.jpg 48w, https:\/\/palas.com.cn\/en\/wp-content\/uploads\/2020\/08\/2-15-600x412.jpg 600w, https:\/\/palas.com.cn\/en\/wp-content\/uploads\/2020\/08\/2-15.jpg 1020w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><br \/>\nThe customer can select a sensor with the appropriate measuring volume size depending on the concentration to be measured.<\/p>\n<p><img loading=\"lazy\" class=\"alignnone size-medium wp-image-5380\" src=\"https:\/\/palas-china.com.cn\/en\/wp-content\/uploads\/2020\/08\/3-14-300x252.jpg\" alt=\"\" width=\"300\" height=\"252\" srcset=\"https:\/\/palas.com.cn\/en\/wp-content\/uploads\/2020\/08\/3-14-300x252.jpg 300w, https:\/\/palas.com.cn\/en\/wp-content\/uploads\/2020\/08\/3-14-768x645.jpg 768w, https:\/\/palas.com.cn\/en\/wp-content\/uploads\/2020\/08\/3-14-24x20.jpg 24w, https:\/\/palas.com.cn\/en\/wp-content\/uploads\/2020\/08\/3-14-36x30.jpg 36w, https:\/\/palas.com.cn\/en\/wp-content\/uploads\/2020\/08\/3-14-48x40.jpg 48w, https:\/\/palas.com.cn\/en\/wp-content\/uploads\/2020\/08\/3-14-600x504.jpg 600w, https:\/\/palas.com.cn\/en\/wp-content\/uploads\/2020\/08\/3-14.jpg 833w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/>For concentrations up to 1,000,000 particles\/cm<sup>3<\/sup>\u00a0the welas<sup>\u00ae<\/sup>\u00a02070 sensor with a small measuring volume is used. This ensures the smallest measuring volume such that only one particle ever enters the measuring volume. In low concentrations, the models with a larger measuring volume offers the advantage of a higher counting rate at the same number concentration.<\/p>\n<p><b>Agreement of the sensors<\/b><br \/>\nThe welas<sup>\u00ae<\/sup>\u00a0sensors are characterized by a particularly good agreement of counting efficiency and particle size resolution.<br \/>\nThis means that the measurement results are highly comparable in terms of the number concentration and particle size measured when using different sensors.<br \/>\n<a class=\"vfsfile image block fancybox\" title=\"\" href=\"https:\/\/www.palas.de\/file\/G32111\/image\/png\/n61258.png.png?size=1200x700\" name=\"vfsfileG32111\" data-fancybox-group=\"fancybox-0f1e1c89759f246d9a5e7dd1276bcfbf\"><img src=\"https:\/\/www.palas.de\/file\/G32111\/image\/png\/n61258.png.png?size=364x200\" alt=\"n61258.png\" \/><\/a><br \/>\nGraph 1: Counting efficiency of various sensors in relation to the welas<sup>\u00ae<\/sup>\u00a02200 sensor (in the measuring range 0.2 \u2013 10 \u00b5m)<\/p>\n<p><b>Pressure-resistant and heatable aerosol sensors with a special cuvette for the variants P, H and HP<\/b><\/p>\n<p>Special measuring cuvettes allow the use of the welas<sup>\u00ae<\/sup>\u00a0aerosol sensors even under unusual measuring conditions. These are available:<br \/>\n<span style=\"color: #008b57;\">\u2022<\/span>\u00a0\u00a0\u00a0\u00a0heatable sensors up to 250\u00b0C; higher temperatures on request<br \/>\n<span style=\"color: #008b57;\">\u2022<\/span>\u00a0\u00a0\u00a0\u00a0pressure-resistant sensors up to 10 bar overpressure<br \/>\n<span style=\"color: #008b57;\">\u2022<\/span>\u00a0\u00a0\u00a0\u00a0sensor resistant against chemically aggressive media<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Aerosol sensor with optical fibre technology for number concentrations up to 1,000,000 particles\/cm<sup>3<\/sup><\/p>\n","protected":false},"featured_media":5394,"template":"","meta":[],"_links":{"self":[{"href":"https:\/\/palas.com.cn\/en\/wp-json\/wp\/v2\/product\/5376"}],"collection":[{"href":"https:\/\/palas.com.cn\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/palas.com.cn\/en\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/palas.com.cn\/en\/wp-json\/wp\/v2\/media\/5394"}],"wp:attachment":[{"href":"https:\/\/palas.com.cn\/en\/wp-json\/wp\/v2\/media?parent=5376"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}