关注微信:

產品

熱線
下載

MFP 3000 HF

Active control of the relative humidity from 10 to 80 % and temperature from -10 to 50 °C

Description

With the new MFP 3000 HF, it is now also possible to set the relative humidity from 10 to 80 % or the temperature from -10 to 50 °C. The inflow velocity has been extended as compared with standard models to a range of 4 cm/s – 2 m/s.

The MFP 3000 HF serves to determine filter parameters under realistic air conditions, such as

    the differential pressure of the filter medium at different inflow velocities
    the fractional efficiency and the differential pressure at a defined air volume flow
    the differential pressure and the fractional efficiency at a defined air volume flow
    the dust holding capacity and the associated gravimetric efficiency at a prescribed air volume flow and increase in differential pressure.

 

Air conditioning

With the MFP 3000 HF, a new test rig concept has been implemented for this purpose, which provides for particularly stable data on air conditioning. This includes an isothermal measuring chain to prevent evaporation and condensation effects of particles in the test channel, as well as during sampling and particle measurement. For this reason, the MFP 3000 HF was equipped with active cooling and heating elements, which allows the air conditioning to be almost independent of the climatic conditions in the lab.

Aerosol generation

The modular system of the MFP 3000 series enables the use of different test aerosols like salt particles, DEHS particles and test dusts like ISO A2 Fine. Aerosol generation is characterized by extremely high consistency in the aerosol concentration and the particle size distribution emitted.

Aerosol measurement from 5 nm to 40 µm

For the first time, the U-SMPS 2100 particle sizer has been integrated into the MFP 3000 series for measurement of nanoparticles in the range from 5 nm to 1 µm. The MFP 3000 HF comes equipped with automatic manual switching between the raw gas and pure gas measurement points.
The light scattering spectrometer Promo® 3000 HP performs clear particle measurements in the range from 200 nm to 40 µm and depending on the choice of sensor also in high concentrations up to 5000 mg/m3 (SAE Fine) or low concentrations for determination of the initial fraction separation efficiency.

Automation

The MFP 3000 has an integrated mass flow controller to control the volume flow. The volume flow rates are automatically monitored and controlled by the FTControl filter test software. The data from the integrated sensors – such as the volume flow, temperature, relative humidity and differential pressure at the filter – are also recorded automatically during the filter test.

Measurement of the fraction separation efficiency

Fig. 3: Example: Comparison of fraction separation efficiencies

    Fully-automated measurement of the fraction separation efficiency
    Clear demonstration of the separation efficiency of your filter medium throughout the entire measurement range from 0.2 to 40 µm with the Promo® system
    Highest measurement reproducibility and repeatability highlight even fine differences in the separation efficiency
    Short measurement times of around 2 minutes per separation efficiency measurement thanks to optimized aerosol application
    Simple comparison of separation efficiency curves, calculation of mean values also possible

 

Sampling and layout

The vertical layout allows even large particles (up to 40 µm) to make their way onto the filter medium. On the raw and clean gas side, isokinetic sampling probes are provided for the raw and clean gas sensor.

Burden / hold time measurement and recording of the pressure loss curve

Fig. 4: Example: Hold time measurement

    Performance of measurements of the fraction separation efficiency during dust application; pressure loss or measurement time can be pre-selected as the abort criterion
    Pre-selectable burden application steps in relation to pressure loss or time
    Gravimetric determination of the separation efficiency
    Determination and display of the pressure loss curve and retention curve in diagram and table form The representation of the particle diameters at 80 % and 95 % separation efficiency provides additional information
    Comparison of the fraction separation efficiencies during the different burdening steps
    Shortening of the measurement times, e.g. through increased aerosol concentration

Additional information

Benefits

<span style="color:#008b57">•</span>    Settable relative humidity: 10 ‒ 80 %
<br> <span style="color:#008b57">•</span>    Temperature regulation of the air volume flow: 20 to 35 °C (-10 to 50 °C on request)
<br> <span style="color:#008b57">•</span>    Expansion of the inflow velocity to 4 cm/s ‒ 2 m/s
<br> <span style="color:#008b57">•</span>    Integration of an U-SMPS into the MFP 3000 HF expands the size range for the measurement of filter efficiency at the MFP 3000 to 10 nm ‒ 40 µm
<br> <span style="color:#008b57">•</span>    Quasi-simultaneous particle measurement in raw gas and pure gas
<br> <span style="color:#008b57">•</span>    Measurement of Cn max= 106 particles/cm3 without dilution
<br> <span style="color:#008b57">•</span>    Internationally comparable measuring results, high distribution of the test system
<br> <span style="color:#008b57">•</span>    Top reproducibility of the test procedure
<br> <span style="color:#008b57">•</span>    Easy use of various test aerosols, such as SAE Fine and Coarse, NaCl/KCl, DEHS
<br> <span style="color:#008b57">•</span>    Top raw gas concentrations up to > 1000 mg/m3 ISO Fine or > 5000 mg/m3 ISO Coarse with fraction separation efficiency measurement for load testing
<br> <span style="color:#008b57">•</span>    Flexible filter test software FTControl
<br> <span style="color:#008b57">•</span>    Sequential programs for pressure loss measurement, fraction separation efficiency measurement and load measurement
<br> <span style="color:#008b57">•</span>    Easy to operate, fast induction even of untrained personnel
<br> <span style="color:#008b57">•</span>    Short set-up times
<br> <span style="color:#008b57">•</span>    Cleaning and calibration can be carried out by customers themselves
<br> <span style="color:#008b57">•</span>    Easy use of the measurement technology components, also in other applications
<br> <span style="color:#008b57">•</span>    For mobile use, easy to move on rollers
<br> <span style="color:#008b57">•</span>    Reliable function
<br> <span style="color:#008b57">•</span>    Demonstration of the clear function of the individual components and the entire system on preliminary acceptance and delivery
<br> <span style="color:#008b57">•</span>    Low maintenance
<br> <span style="color:#008b57">•</span>    Reduces your operating expenses

Applications

<span style="color:#008b57">•</span>    Testing of filter media and of small filter elements in product development and during production monitoring with variable rel. humidity and temperature.
<br> <span style="color:#008b57">•</span>    Testing option based on ISO 11155-1 / DIN 71460-1 (cabin air filters), ISO 5011 (engine pre-air filters), ISO 16890 / EN779 / ASHRAE 52.2 (room air filters), EN 1822-3 (HEPA filters), CEN EN 143 and other standards in various versions.
<br> <span style="color:#008b57">•</span>    Simulation for testing
<br>       <span style="color:#008b57">-</span>   car interior air intake filters or engine air filters at high temperatures, under dusty and dry or extremely humid conditions
<br>       <span style="color:#008b57">-</span>   turbine air filters from power plants (like those exposed to salt particles at high humidity on the coast under bad weather condition)
<br>       <span style="color:#008b57">-</span>   performance of room air filters in summer (warm and humid / dry) and winter (cold / humid / dry)
<br>       <span style="color:#008b57">-</span>   performance of ice formation in the filter medium

Measurement range (size)

0.2 – 40 µm (Promo® system), 5 – 1 µm (U-SMPS system)

Volume flow

1.2 – 72 m3/h (suction mode)

Power supply

400 V, 50 Hz

Dimensions

2,300 • 800 • 2,000 mm (H • W • D)

Temperature regulation

20 – 35 °C (-10 – 50 °C on request)

Luftfeuchteregelung

10 – 80 %

Inflow velocity

4 – 200 cm/s

Differential pressure measurement

0 – 20,000 Pa

Test area of the medium

100 cm2

Aerosols

Dusts (e. g. SAE dusts), salts (e. g. NaCl, KCl), liquid aerosols (e. g. DEHS)

Aerosol concentrations

For SAE-Fine without additional dilution to 1,000 mg/m3 (ISO A2 Fine)

Compressed air supply

6 – 8 bar