Liquid nebulizer with binary nozzle and cyclone (dp_max = 2 µm) as per VDI 3491-1 and -2

Category:

Description

The AGF 2.0 is an aerosol generator for the atomization of liquids and latex suspensions with a constant particle rate and defined particle spectrum.

Fig. 1: AGF 2.0

The AGF 2.0 system comprises an adjustable binary nozzle for adjustment of the desired mass flow and a cyclone with a cut-off of 2 µm. As a result, virtually no particles > 2 µm are generated.

AGF 2.0 functional principle

Fig. 2: Functional principle of the AGF series, including cyclone

Startup

The liquid to be dispersed is filled in the reservoir and the AGF 2.0 is connected to the compressed air connection. A manometer enables the mass flow of the liquid to be continuously adjusted using the primary pressure on the nozzle. The mist of droplets generated by the nozzle flows tangentially into a cyclone. Large particles are separated here by centrifugal force and drip back into the reservoir. The remaining droplets leave the cyclone via the so-called “immersion tube”. The size spectrum of these droplets is determined on the one hand by the primary droplet spectrum generated by the nozzle, but especially by the separation characteristics of the cyclone on the other hand.

The separation size is able to be calculated: daerodyn.max = 2 µm, i.e. regardless of the liquid to be atomized, the max. particle size is daerodyn ≈ 2 µm.

Table 1: Overview of the AGF and UGF systems

Additional information

Benefits

<span style="color:#008b57">•</span>    Exact adjustment of the operating parameters
<br> <span style="color:#008b57">•</span>    Number concentration (CN) can be varied by the factor 10
<br> <span style="color:#008b57">•</span>    Particle size distribution remains virtually constant, if CN is modified
<br> <span style="color:#008b57">•</span>    Number distribution maximum is within the MPPS range
<br> <span style="color:#008b57">•</span>    Virtually no power losses
<br> <span style="color:#008b57">•</span>    Optimal concentration, no coagulation losses
<br> <span style="color:#008b57">•</span>    Resistant to numerous acids, bases, and solvents
<br> <span style="color:#008b57">•</span>    Robust design, stainless steel housing
<br> <span style="color:#008b57">•</span>    Easy to operate
<br> <span style="color:#008b57">•</span>    As opposed to the collision method, the AGF 2.0 does not generate any particles > 2 µm thanks to its cyclone.
<br> <span style="color:#008b57">•</span>    Due to the fact that the AGF generates virtually no droplets > 2 µm, the consumption of materials is very low, thus ensuring a long dosing time.
<br> <span style="color:#008b57">•</span>    With the use of DEHS the mean particle size is within the MPPS range for HEPA/ULPA filters

Applications

<span style="color:#008b57">•</span>     <b style="font-weight: bold;"> Clean room technology</b>
<br>       <span style="color:#008b57">-</span>   Acceptance tests and leak tests as per ISO 14644 and VDI 2083
<br>       <span style="color:#008b57">-</span>   Leak tests, fit testing
<br>       <span style="color:#008b57">-</span>   Recovery tests
<br> <span style="color:#008b57">•</span>     <b style="font-weight: bold;">Filter testing, quality control</b>
<br>       <span style="color:#008b57">-</span>   Filter cartridges
<br>       <span style="color:#008b57">-</span>   Car interior filters
<br>       <span style="color:#008b57">-</span>   Filter media, particulate air filters
<br>       <span style="color:#008b57">-</span>   Aerosol generation for MPPS determination of HEPA/ULPA filters
<br> <span style="color:#008b57">•</span>     <b style="font-weight: bold;"> Tracer particles</b>
<br>       <span style="color:#008b57">-</span>   Inhalation experiments
<br>       <span style="color:#008b57">-</span>   Optical flow measurement procedures with positive pressure values of up to 10 bar (model version AGF 2.0 D)
<br>       <span style="color:#008b57">-</span>   LDV
<br> <span style="color:#008b57">•</span>     <b style="font-weight: bold;">Calibration of counting particle measurement methods</b>
<br>       <span style="color:#008b57">-</span>   Nebulization of latex suspensions < 1 µm
<br> <span style="color:#008b57">•</span>     <b style="font-weight: bold;">Smoke detector test</b>

Volume flow

6 – 17 l/min

Dimensions

300 • 330 • 240 mm

Weight

approx. 9 kg

Particle material

DEHS, DOP, Emery 3004, paraffin oil, other non-resinous oils

Dosing time

> 24 h

Mass flow (particles)

< 4 g/h (DEHS)

Compressed air connection

Quick coupling

Aerosol outlet connection

Øinside = 6 mm, Øoutside = 8 mm

Mean particle diameter (number)

0.25 µm

Biggest particle diameter

2 µm

Filling quantity

300 ml